Most truss is bought on tube size and price. Most truss problems happen because nobody read the load table.

A load table is the only document that tells you what a section can carry at the span you actually plan to use. It is also the document most often skipped, because the numbers look abstract until something sags — or worse.

This guide explains how to read one: what the columns mean, why the same truss carries so much less over a longer span, and which loads people forget to count.

What a load table actually tells you

A proper table is not one number. It is a grid: span across the top, permissible load down the side, usually with a deflection figure attached.

Read it in this order:

  1. Find your span. Stage to stage, support to support — the distance between load points, not the length of the truss you bought.
  2. Find your load type. Uniformly distributed (UDL) and point load (CL, centre point) are separate columns. Mixing them up is the single most common rigging error.
  3. Read the deflection column. It tells you how much the truss bends at that load, which matters as much as whether it holds.
  4. Check the notes. Support conditions, maximum cantilever, and whether the figures assume a specific hang pattern.

A supplier who gives you "up to 500 kg" with no span attached has given you nothing usable.

Uniform load vs point load

Uniformly distributed load spreads across the span — a lighting bar with fixtures along its length, an LED wall hanging from multiple points, a line of par cans.

Point load sits in one place — a single heavy mover, a speaker cabinet on one hook, a chain hoist picking up at centre.

The same truss handles these very differently. A centre point load produces the highest bending moment for the same total weight, so the permissible total load in a CL column is usually much lower than in the UDL column at the same span. If your rig is four fixtures spread evenly, reading the UDL column is right. If it is one heavy item in the middle, you must read the CL column — or add a second pick-up point.

Why span changes everything

Capacity does not fall in a straight line as span increases. It falls much faster, because bending moment grows with span while the section's resistance stays fixed.

Practically: a section that carries a comfortable load at 6 m may carry a small fraction of it at 12 m. This is why "what can this truss hold" is not a question with an answer — only "what can it hold at this span, with this load pattern" is.

The same logic applies to towers and ground support: height is span turned vertical. A leg at 2 m and the same leg at 5 m are different structures.

Deflection: the number people ignore

A truss can be within its load rating and still be wrong for the job, because it sags.

Deflection limits are usually expressed as a fraction of span — L/100 or L/200 are common reference points, with the stricter figure used where sightlines, camera framing or moving scenery matter.

Why it matters on site:

  • Lighting focus drifts. A bar that sags under load puts every fixture off its aim.
  • LED walls show it. Panels that were flush at ground level develop visible steps when the supporting truss bends.
  • Movement reads on camera. Even a small oscillation at the centre of a long span is visible on a long lens.
  • Doors and scenery bind. Anything rolling or folding under a deflected truss will fight its track.

If the table gives load but no deflection, ask for the deflection at your span and load. It is the difference between "it held" and "it worked".

The loads people forget

Real rigs are heavier than the gear list suggests. Count these before you compare against the table:

  • Cabling and data. Power and signal runs, especially on long spans, add up.
  • Clamps, couplers and safety bonds. Small individually, not small in quantity.
  • Scenery and drapes. Backdrops, borders and legs, plus the track they hang from.
  • Dynamic effects. Anything that moves, swings or is struck transfers more than its static weight.
  • People. If anyone is working on the truss during build, that is a load too.
  • Snow, wind and water for outdoor structures — check local requirements; these can govern the design entirely.

Then apply a margin. Load tables describe limits, not comfortable working conditions.

Reading a table for your rig: the sequence

  1. Measure the real span between pick-up points.
  2. List every item on the truss and total the weight, then add cabling and hardware.
  3. Decide whether the load is closer to UDL or a centre point.
  4. Read the corresponding column at your span.
  5. Compare not just load but deflection against what the show needs.
  6. Confirm the pick-up points, motors and their ratings separately — the truss is only one link in the chain.
  7. If you are near a limit, add a pick-up point rather than buying a heavier section. Extra support is usually cheaper and always safer.

Questions to ask before you hang anything

  • What span and load pattern do these figures apply to?
  • Is the rating static, and does it account for dynamic effects?
  • What is the deflection at my span and load?
  • What is the maximum cantilever, and what applies beyond it?
  • Which accessories — corners, sleeve blocks, base plates — carry their own ratings?
  • What is the inspection interval, and what disqualifies a section?

FAQ

Can I hang more if I add a pick-up point?

Usually yes, and it is the cheapest fix. Reducing span raises capacity far more than upsizing the section at the same span.

Is a bigger tube always stronger?

Not by itself. Chord size, wall thickness, bracing pattern and span all contribute. Compare sections using their own tables at your span, not by eye.

What does L/200 mean?

The maximum permitted sag is span divided by 200. At 10 m, that is 50 mm. A stricter limit (L/300 or tighter) is sometimes required for camera work or precision scenery.

Can I use one table for a different brand's truss?

No. Tolerances, materials and bracing differ. Use the manufacturer's table for that specific section.

Explore our full range

We supply new and used equipment for stage and event projects:

  • Aluminium stage truss — box, spigot, bolted and circular sections
  • Aluminium stage platforms, guardrails and stairs
  • Lifting towers and ground support systems
  • Crowd barriers and flight cases
  • Stage lighting clamps and LED screen brackets
  • Used stage lighting, used LED screens, used speakers and used truss

ส่งคำถามของคุณโดยตรงกับเรา

นโยบายความเป็นส่วนตัว จีน คุณภาพดี อลูมิเนียม สเตจทราส ผู้จัดจําหน่าย.ลิขสิทธิ์ 2025-2026 Guangzhou Fengsheng Performance Equipment Co., Ltd สิทธิทั้งหมดถูกเก็บไว้