2026-11-25
Most truss failures are not sudden. They are the end of a sequence: a bent section that kept being used, a pin that was never replaced, a weld that had been cracked for two seasons. None of it is visible from the audience, which is exactly why inspection has to be a routine rather than a reaction.
This checklist is written for the people who actually handle the kit — rental warehouse staff, touring crew, venue technicians and production managers — and covers what to look at, how often, and when a section should leave service.
It is rarely laziness. Three structural problems make inspection fail even when people care:
A written checklist with a named person and a clear retirement rule fixes all three.
Five minutes per bundle, before anything goes up. Purpose: catch anything that happened since the last show — transit damage, a bad drop, a section used as a workbench. This is a visual and tactile check, done with the truss on the ground where you can see all four sides.
A fuller inspection, recorded, ideally by someone trained for it. Purpose: find what a five-minute walk-round cannot — cracked welds under paint, ovalised spigot holes, fatigue at brace junctions, cumulative corrosion. This is the record that satisfies insurers, venues and clients who ask how the equipment is maintained.
Run a hand along each chord. You are feeling for dents, flat spots and local kinks. Then sight down the length from one end: a straight section should look straight, and a section with a visible curve is already out.
Pay attention to the area around the end plates, where handling damage concentrates, and to the mid-span of long sections, where overload shows first.
Look at every weld you can see, especially where braces meet chords. Reject on:
Spigot connections depend on a close fit. Check for ovalised pin holes, worn or burred spigots, bent end plates and elongation around bolt holes on bolted systems. A connection that needs force to assemble is telling you something.
Consumables, and the cheapest thing on the checklist to replace. Bent pins, missing R-clips and bolts with damaged threads should be replaced, not reused. Keep spares in the flight case so replacement is easier than reuse.
Bracing carries shear and keeps the section from racking. A bent or missing brace changes how the section behaves under load, and a section with a missing brace must not go up. Check that braces are straight between nodes and firmly attached at both ends.
Lay the section on a flat surface and check for rock and twist. Twist is harder to see than bend and more damaging, because it misaligns every connection along the run. Two sections that will not sit flat together will not assemble cleanly on site either.
Aluminium does not rust like steel, but it corrodes — typically white powdery deposits in crevices, at weld toes and under damaged anodising. Corrosion at a joint is a structural concern, not a cosmetic one. Powder coat hides cracks; if the coating is cracked or lifting, inspect the metal underneath.
Corners, T-pieces, base plates, sleeve blocks and clamps carry their own loads and their own damage. A bent corner is not repairable by eye, and a base plate with a distorted flange will not sit flat. Include them in the same inspection and the same records.
Give every section an identifier — a stamped number, a durable label or a colour code by purchase batch. Record the inspection date, inspector, findings and action. Then tag the physical section: in service, restricted use, or quarantined.
Quarantine has to be physical. A section marked in a spreadsheet but returned to the rack will be used on the next job by someone who never saw the spreadsheet.
Retire rather than repair when:
Cutting and re-welding a damaged node is not a field repair. Without re-heat-treatment and re-testing, the repair has no rating, and an unrated section in a rated rig is a liability.
Inspection tells you the condition of what you can see. It cannot tell you the load history. A section that has been overloaded may look straight and still have lost capacity through fatigue at the nodes.
When buying used, ask for the section's load table, its age, and whether it has been in a documented incident. Then inspect it as if the answers were unsatisfactory. Our guide to buying used stage equipment covers the commercial side of that decision.
A visual check before every build, and a documented inspection at least annually — more often for rental fleets, touring kit and outdoor structures, where handling and weather exposure are higher.
You can, but it hides the evidence. Treat corrosion and cracked coating as findings to record, not cosmetic issues to cover.
No. Bend means the section has already been loaded beyond its elastic range, and its capacity is no longer described by the load table. Retire it.
Inspection is what keeps a rated system rated. Our aluminium stage truss and used stage truss ranges ship with load tables and TÜV documentation, and our quality control process covers weld inspection and dimensional checks before dispatch. If you need replacement sections, pins or spares for an existing rig, send the section details through our contact form.